N- PROPANOL

Table of Contents

N- PROPANOL

CAS NO:71-23-8

 

SYNONYMS
1-propanol;propanol;Propan-1-ol;n-propanol;Propyl alcohol;71-23-8;n-Propyl alcohol;ethylcarbinol;1-hydroxypropane;optal;osmosol extra;Propylic alcohol;Propanol-1;1-Propyl alcohol;n-Propan-1-ol;Propanolen;Propanole;Alcohol, propyl;Propanoli;Ethyl carbinol;Alcool propilico;Alcool propylique;n-Propyl alkohol;Propylowy alkohol;Albacol;1 Propanol;propane-1-ol;Propanole [German];Propanolen [Dutch];Propanol, 1-;Propanoli [Italian];propylalcohol;Propyl alcohol, normal;Caswell No. 709A;1-PROPONOL;FEMA Number 2928;Propyl alcohol (natural);n-Propyl alkohol [German];Alcool propilico [Italian];Alcool propylique [French];Propylowy alkohol [Polish];NSC 30300;UNII-96F264O9SV;FEMA No. 2928;CCRIS 3202;HSDB 115;Propylan-propyl alcohol;EINECS 200-746-9;UN1274;RL04721;RTR-023458;TRA0060291;1-Propanol, ACS reagent, >=99.5%;1-Propanol, HPLC grade, >=99.5%;CAS-71-23-8;1-Propanol, purum, >=99.0% (GC);NCGC00255163-01;AN-41945;KB-66585;1-Propanol, SAJ first grade, >=99.0%;Propyl Alcohol (Normal) Reagent Grade ACS;TR-023458;FT-0608280;FT-0627482;P0491;1-Propanol, UV HPLC spectroscopic, 99.0%;2537-EP2269989A1;2537-EP2269993A1;2537-EP2269994A1;2537-EP2295053A1;2537-EP2298313A1;27313-EP2311808A1;27313-EP2311829A1;27313-EP2311830A1;27313-EP2314575A1;136983-EP2275411A2;136983-EP2292606A1;A837125;I14-2607;InChI=1/C3H8O/c1-2-3-4/h4H,2-3H2,1H;J-505102;1-Propanol, for inorganic trace analysis, >=99.8%;1-Propanol, B&J Brand (product of Burdick & Jackson);F0001-1829;Z955123580;1-Propanol, puriss. p.a., Reag. Ph. Eur., >=99.5% (GC);1-Propanol, United States Pharmacopeia (USP) Reference Standard;n-Propanol or propyl alcohol, normal [UN1274] [Flammable liquid];n-Propanol or propyl alcohol, normal [UN1274] [Flammable liquid];1-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material;5VQ

N-Propanol is a primary alcohol with the formula CH3CH2CH2OH (sometimes represented as PrOH or n-PrOH). This colorless liquid is also known as propan-1-ol, 1-propyl alcohol, n-propyl alcohol, and n-propanol. It is an isomer of 2-propanol (propan-2-ol, isopropyl alcohol, isopropanol). It is formed naturally in small amounts during many fermentation processes and used as a solvent in the pharmaceutical industry mainly for resins and cellulose esters.

CHEMICAL PROPERTIES
1-Propanol shows the normal reactions of a primary alcohol. Thus it can be converted to alkyl halides; for example red phosphorus and iodine produce n-propyl iodide in 80% yield, while PCl3 with catalytic ZnCl2 gives n-propyl chloride. Reaction with acetic acid in the presence of an H2SO4 catalyst under Fischer esterification conditions gives propyl acetate, while refluxing propanol overnight with formic acid alone can produce propyl formate in 65% yield. Oxidation of 1-propanol with Na2Cr2O7 and H2SO4 gives only a 36% yield of propionaldehyde, and therefore for this type of reaction higher yielding methods using PCC or the Swern oxidation are recommended. Oxidation with chromic acid yields propionic acid.

PREPARATION
1-Propanol is manufactured by catalytic hydrogenation of propionaldehyde. The propionaldehyde is itself produced via the oxo process, by hydroformylation of ethylene using carbon monoxide and hydrogen in the presence of a catalyst such as cobalt octacarbonyl or a rhodium complex.
H2C=CH2 + CO + H2 → CH3CH2CH=O
CH3CH2CH=O + H2 → CH3CH2CH2OH
A traditional laboratory preparation of 1-propanol involves treating n-propyl iodide with moist Ag2O.
N-Propanol was discovered in 1853 by Gustave C. B. Chancel, who obtained it by fractional distillation of fusel oil. Indeed, 1-propanol is a major constituent of fusel oil, a by-product formed from certain amino acids when potatoes or grains are fermented to produce ethanol. This process is no longer a significant source of 1-propanol.
SAFETY
N-Propanol is thought to be similar to ethanol in its effects on the human body, but 2-4 times more potent. Oral LD50 in rats is 1870 mg/kg (compared to 7060 mg/kg for ethanol). It is metabolized into propionic acid. Effects include alcoholic intoxication and high anion gap metabolic acidosis. As of 2011, only one case of lethal 1-propanol poisoning was reported.

INHALATION
Although this method is rare, it does exist. Propanol might be much more convenient than ethanol for inhalation because of its potency with nebulizers.
Propanol as fuel
1-propanol has high octane numbers and it is suitable for engine fuel usage. However, the production of propanol has been too expensive to make it a common fuel. The research octane number (RON) of propanol is 118 and anti-knock index (AKI) is 108.

SAFETY AND HAZARDS
Hazards Identification
GHS Hazard Statements
Aggregated GHS information provided by 2587 companies from 43 notifications to the ECHA C&L Inventory. Each notification may be associated with multiple companies.
Reported as not meeting GHS hazard criteria by 1 of 2587 companies. For more detailed information, please visitECHA C&L website Of the 42 notification(s) provided by 2586 of 2587 companies with hazard statement code(s):

H225 (100%): Highly Flammable liquid and vapor [Danger Flammable liquids]
H302 (13.96%): Harmful if swallowed [Warning Acute toxicity, oral]
H318 (100%): Causes serious eye damage [Danger Serious eye damage/eye irritation]
H336 (99.81%): May cause drowsiness or dizziness [Warning Specific target organ toxicity, single exposure; Narcotic effects]

Information may vary between notifications depending on impurities, additives, and other factors. The percentage value in parenthesis indicates the notified classification ratio from companies that provide hazard codes. Only hazard codes with percentage values above 10% are shown.

Precautionary Statement Codes
P210, P233, P240, P241, P242, P243, P261, P264, P270, P271, P280, P301+P312, P303+P361+P353, P304+P340, P305+P351+P338, P310, P312, P330, P370+P378, P403+P233, P403+P235, P405, and
Health Hazard
Contact with eyes is extremely irritating and may cause burns. Vapors irritate nose and throat. In high concentrations, may cause nausea, dizziness, headache, and stupor. (USCG, 1999)
Flammable – 3rd degree
Fire Hazard
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]: HIGHLY FLAMMABLE: Will be easily ignited by heat, sparks or flames. Vapors may form explosive mixtures with air. Vapors may travel to source of ignition and flash back. Most vapors are heavier than air. They will spread along ground and collect in low or confined areas (sewers, basements, tanks). Vapor explosion hazard indoors, outdoors or in sewers. Those substances designated with a (P) may polymerize explosively when heated or involved in a fire. Runoff to sewer may create fire or explosion hazard. Containers may explode when heated. Many liquids are lighter than water.
Highly flammable. Gives off irritating or toxic fumes (or gases) in a fire. Vapour/air mixtures are explosive.
Fire Potential
Dangerous upon exposure to heat or flame; can react vigorously with oxidizing materials.
Ignites on contact with potassium-tert-butoxide.
Skin, Eye, and Respiratory Irritations
EXPOSURE TO 400 PPM FOR 3 T0 5 MIN PRODUCED MILD IRRITATION OF EYES, NOSE, AND THROAT.
High concn … can cause CNS depression & are irritating to the eyes, throat, & mucous membranes. Contact to the skin of the liquid can cause mild chemical burns.
Safety and Hazard Properties
LEL
2.1 % (USCG, 1999)
2.2%
UEL
13.5 % (USCG, 1999)
13.7%
Flammability
Lower flammable limit: 2.2% by volume; Upper flammable limit: 13.7% by volume
Class IB Flammable Liquid: Fl.P. below 73°F and BP at or above 100°F.
Critical Temperature
Critical temp: 263.7 deg C; critical pressure: 51 atm
Critical Pressure
Critical temp: 263.7 deg C; critical pressure: 51 atm
NFPA Hazard Classification
Health: 1. 1= Materials that, on exposure, would cause irritation, but only minor residual injury, including those requiring the use of an approved air-purifying respirator. These materials are only slightly hazardous to health and only breathing protection is needed.
Flammability: 3. 3= This degree includes Class IB and IC flammable liquids and materials that can be easily ignited under almost all normal temperature conditions. Water may be ineffective in controlling or extinguishing fires in such materials.
Reactivity: 0. 0= This degree includes materials that are normally stable, even under fire exposure conditions, and that do not react with water. Normal fire fighting procedures may be used.
NFPA Fire Rating
3
NFPA Health Rating
1
Physical Dangers
The vapour mixes well with air, explosive mixtures are easily formed.

Chemical Dangers
800 ppm
Reacts with strong oxidants. This generates fire and explosion hazard. Attacks some forms of plastic and rubber.
Explosive Limits and Potential
LOWER 2.1%, UPPER 13.5%
Explosive in the form of vapor when exposed to heat or flame.
Explosive limits , vol% in air: 2.1-13.5
OSHA Standards
Permissible Exposure Limit: Table Z-1 8-hr Time Weighted Avg: 200 ppm (500 mg/cu m).
Vacated 1989 OSHA PEL TWA 200 ppm (500 mg/cu m); STEL 250 ppm (625 mg/cu m) is still enforced in some states.
NIOSH Recommendations
Recommended Exposure Limit: 10 Hr Time-Weighted Avg: 200 ppm (500 mg/cu m).
Recommended Exposure Limit: 15 Min Short-Term Exposure Limit: 250 ppm (625 mg/cu m) [skin].
First Aid Measures
First Aid
Eye: If this chemical contacts the eyes, immediately wash the eyes with large amounts of water, occasionally lifting the lower and upper lids. Get medical attention immediately. Contact lenses should not be worn when working with this chemical. Skin: If this chemical contacts the skin, flush the contaminated skin with water. Where there is evidence of skin irritation, get medical attention. Breathing: If a person breathes large amounts of this chemical, move the exposed person to fresh air at once. If breathing has stopped, perform mouth-to-mouth resuscitation. Keep the affected person warm and at rest. Get medical attention as soon as possible. Swallow: If this chemical has been swallowed, get medical attention immediately.

Eye:Irrigate immediately
Skin:Water flush
Breathing:Respiratory support
Swallow:Medical attention immediately
Inhalation First Aid
Fresh air, rest.
Skin First Aid
Rinse and then wash skin with water and soap.
Eye First Aid
First rinse with plenty of water for several minutes (remove contact lenses if easily possible), then refer for medical attention.
Ingestion First Aid
Rinse mouth. Refer for medical attention .
Fire Fighting Measures
To fight fire use alcohol foam, carbon dioxide, dry chemical.
/During/ fire fighting self-contained breathing apparatus with full facepiece operated in pressure demand or other positive pressure mode /should be worn./

Fire Fighting
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]: CAUTION: All these products have a very low flash point: Use of water spray when fighting fire may be inefficient. SMALL FIRE: Dry chemical, CO2, waterspray or alcohol-resistant foam. Do not use dry chemical extinguishers to control fires involving nitromethane(UN1261) or nitroethane (UN2842). LARGE FIRE: Water spray, fog or alcohol-resistant foam. Do not use straight streams. Move containers from fire area if you can do it without risk. FIRE INVOLVING TANKS OR CAR/TRAILER LOADS: Fight fire from maximum distance or use unmanned hose holders or monitor nozzles. Cool containers with flooding quantities of water until well after fire is out. Withdraw immediately in case of rising sound from venting safety devices or discoloration of tank. ALWAYS stay away from tanks engulfed in fire. For massive fire, use unmanned hose holders or monitor nozzles; if this is impossible, withdraw from area and let fire burn.
Use water spray, powder, alcohol-resistant foam, carbon dioxide. In case of fire: keep drums, etc., cool by spraying with water.
Other Fire Fighting Hazards
Flash back along vapor trail may occur.
Isolation and Evacuation
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]: As an immediate precautionary measure, isolate spill or leak area for at least 50 meters (150 feet) in all directions. LARGE SPILL: Consider initial downwind evacuation for at least 300 meters (1000 feet). FIRE: If tank, rail car or tank truck is involved in a fire, ISOLATE for 800 meters (1/2 mile) in all directions; also, consider initial evacuation for 800 meters (1/2 mile) in all directions. (ERG, 2016)
Spillage Disposal
Ventilation. Remove all ignition sources. Collect leaking and spilled liquid in sealable containers as far as possible. Absorb remaining liquid in sand or inert absorbent. Then store and dispose of according to local regulations.
Cleanup Methods
Absorb on paper. Evaporate on a glass or iron dish in hood. Burn the paper.
Countermeasures recommended for treating spills: activated charcoal, biological treatment agent, gelling agent, absorbing agent, dispersing agent.
Disposal Methods
SRP: At the time of review, criteria for land treatment or burial (sanitary landfill) disposal practices are subject to significant revision. Prior to implementing land disposal of waste residue (including waste sludge), consult with environmental regulatory agencies for guidance on acceptable disposal practices.

1. By absorbing it in vermiculite, dry sand, earth or a similar material and disposing in an … /approved/ sanitary landfill. 2. By atomizing in a suitable combustion chamber.
The following wastewater treatment technologies have been investigated for n-propanol: Biological treatment.
Incineration: Waste liquid can be atomized in an incinerator or can be disposed of by way of a licensed solvent disposal company or can be reclaimed.
Other Preventative Measures
Adequate ventilation … /is/ necessary.
Clothing wet with liquid propyl alcohol should be placed in closed containers for storage until it can be discarded or until provision is made for removal of propyl alcohol from the clothing. If … laundered or otherwise cleaned to remove the propyl alcohol, the person performing the operation should be informed of propyl alcohol’s hazardous properties. Any clothing which becomes wet with liq … should be removed immediately & not reworn until propyl alcohol is removed from the clothing.
SRP: The scientific literature for the use of contact lenses in industry is conflicting. The benefit or detrimental effects of wearing contact lenses depend not only upon the substance, but also on factors including the form of the substance, characteristics and duration of the exposure, the uses of other eye protection equipment, and the hygiene of the lenses. However, there may be individual substances whose irritating or corrosive properties are such that the wearing of contact lenses would be harmful to the eye. In those specific cases, contact lenses should not be worn. In any event, the usual eye protection equipment should be worn even when contact lenses are in place.
SRP: Contaminated protective clothing should be segregated in such a manner so that there is no direct personal contact by personnel who handle, dispose, or clean the clothing. Quality assurance to ascertain the completeness of the cleaning procedures should be implemented before the decontaminated protective clothing is returned for reuse by the workers. Contaminated clothing should not be taken home at end of shift, but should remain at employee’s place of work for cleaning.
Employees who handle liquid isobutyl alcohol should wash their hands before eating or smoking. /Isobutyl alcohol/
The worker should immediately wash the skin when it becomes contaminated.
Work clothing that becomes wet should be immediately removed due to its flammability hazard.
Handling and Storage
Nonfire Spill Response
Excerpt from ERG Guide 129 [Flammable Liquids (Water-Miscible / Noxious)]: ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). All equipment used when handling the product must be grounded. Do not touch or walk through spilled material. Stop leak if you can do it without risk. Prevent entry into waterways, sewers, basements or confined areas. A vapor-suppressing foam may be used to reduce vapors. Absorb or cover with dry earth, sand or other non-combustible material and transfer to containers. Use clean, non-sparking tools to collect absorbed material. LARGE SPILL: Dike far ahead of liquid spill for later disposal. Water spray may reduce vapor, but may not prevent ignition in closed spaces. (ERG, 2016)
Safe Storage
Fireproof. Separated from strong oxidants. Cool. Well closed. Keep in a well-ventilated room.
Storage Conditions
Keep containers closed, store in cool, well ventilated place away from ignition sources.
Exposure Control and Personal Protection
REL
TWA 200 ppm (500 mg/m3) ST 250 ppm (625 mg/m3) [skin]
PEL-TWA
200 ppm (500 mg/m³) ppm
REL-TWA
200 ppm (500 mg/m³) ppm
REL-STEL
250 ppm (625 mg/m³) ppm
IDLH
800 ppm (NIOSH, 2016)
800 ppm ppm
800 ppm

Threshold Limit Values
8 hr Time Weighted Avg (TWA): 100 ppm

Excursion Limit Recommendation: Excursions in worker exposure levels may exceed 3 times the TLV-TWA for no more than a total of 30 minutes during a work day, and under no circumstances should they exceed 5 times the TLV-TWA, provided that the TLV-TWA is not exceeded.
A4: Not classifiable as a human carcinogen.
100 ppm as TWA; A4 (not classifiable as a human carcinogen)
Other Occupational Permissible Levels
Other recommendations: West Germany (1974) 200 ppm; Czechoslovakia (1969), East Germany (1973) 100 ppm; USSR (1972) 50 ppm.
A harmful contamination of the air will be reached rather slowly on evaporation of this substance at 20°C; on spraying or dispersing, however, much faster.
Effects of Short Term Exposure
The substance is irritating to the eyes. The substance may cause effects on the central nervous system. Exposure at high levels could cause unconsciousness.
Effects of Long Term Exposure
The substance defats the skin, which may cause dryness or cracking.
Allowable Tolerances
Residues of n-propanol are exempted from the requirement of a tolerance when used as a solvent or cosolvent in accordance with good agricultural practice as inert (or occasionally active) ingredients in pesticide formulations applied to growing crops or to raw agricultural commodities after harvest.
n-Propanol is exempted from the requirement of a tolerance when used as a solvent for blended emulsifiers in accordance with good agricultural practice as inert (or occasionally active) ingredients in pesticide formulations applied to growing crops only.
n-Propanol is exempted from the requirement of a tolerance when used as a solvent for blended emulsifiers in accordance with good agricultural practice as inert (or occasionally active) ingredients in pesticide formulations applied to animals.
Personal Protection

Skin:Prevent skin contact
Eyes:Prevent eye contact
Wash skin:When contaminated
Remove:When wet (flammable)
Change:No recommendation

Respirator Recommendations
NIOSH/OSHA
Up to 800 ppm:
(APF = 10) Any chemical cartridge respirator with organic vapor cartridge(s)*
(APF = 25) Any powered, air-purifying respirator with organic vapor cartridge(s)*
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
(APF = 10) Any supplied-air respirator*
(APF = 50) Any self-contained breathing apparatus with a full facepiece
Emergency or planned entry into unknown concentrations or IDLH conditions:
(APF = 10,000) Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode
(APF = 10,000) Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained positive-pressure breathing apparatus
Escape:
(APF = 50) Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister
Any appropriate escape-type, self-contained breathing apparatus
Fire Prevention
NO open flames, NO sparks and NO smoking. NO contact with oxidizing agents. Closed system, ventilation, explosion-proof electrical equipment and lighting. Do NOT use compressed air for filling, discharging, or handling.
Inhalation Prevention
Use ventilation, local exhaust or breathing protection.
Skin Prevention
Protective gloves.
Eye Prevention
Wear safety goggles.
Ingestion Prevention
Do not eat, drink, or smoke during work.
Protective Equipment and Clothing
Skin: Wear appropriate personal protective clothing to prevent skin contact. Eyes: Wear appropriate eye protection to prevent eye contact. Wash skin: The worker should immediately wash the skin when it becomes contaminated. Remove: Work clothing that becomes wet should be immediately removed due to its flammability hazard(i.e. for liquids with flash point < 100°F) Change: No recommendation is made specifying the need for the worker to change clothing after the work shift. (NIOSH, 2016)
Employees should be provided with & required to use impervious clothing … & other appropriate clothing necessary to prevent repeated or prolonged skin contact with liquid propyl alcohol. … Employees should be provided with & required to use splash proof safety goggles where liquid propyl alcohol may contact the eyes.
Wear rubber gloves, face shield, overalls … .
Breakthrough times greater than one hour reported by (normally) two or more testers for neoprene and nitrile rubber. Some data (usually from immersion tests) suggesting breakthrough times greater than one hour are not likely for natural rubber. No data for butyl rubber, neoprene /styrene-butadiene rubber, polyvinyl chloride, polyethylene, polyurethane, polyvinyl alcohol and viton. Some data suggesting breakthrough times of approximated an hour or more for polyvinyl chloride (PVC).
Wear appropriate personal protective clothing to prevent skin contact.
Wear appropriate eye protection to prevent eye contact.
Recommendations for respirator selection. Max concn for use: 800 ppm. Respirator Class(es): Any chemical cartridge respirator with organic vapor cartridge(s). May require eye protection. Any powered, air-purifying respirator with organic vapor cartridge(s). May require eye protection. Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister. Any supplied-air respirator. May require eye protection. Any self-contained breathing apparatus with a full facepiece.
Recommendations for respirator selection. Condition: Emergency or planned entry into unknown concn or IDLH conditions: Respirator Class(es): Any self-contained breathing apparatus that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode. Any supplied-air respirator that has a full facepiece and is operated in a pressure-demand or other positive-pressure mode in combination with an auxiliary self-contained breathing apparatus operated in pressure-demand or other positive-pressure mode.
Recommendations for respirator selection. Condition: Escape from suddenly occurring respiratory hazards: Respirator Class(es): Any air-purifying, full-facepiece respirator (gas mask) with a chin-style, front- or back-mounted organic vapor canister. Any appropriate escape-type, self-contained breathing apparatus.

STABILITY AND REACTIVITY
Air and Water Reactions
Highly flammable. Water soluble.
Alcohols and Polyols
Reactivity Alerts
Highly Flammable
Reactivity Profile
N-PROPANOL reacts with alkali metal, nitrides and strong reducing agents to give flammable and/or toxic gases. Reacts with oxoacids and carboxylic acids to form esters plus water. Converted by oxidizing agents to propanal or propionic acid. May initiate the polymerization of isocyanates and epoxides. Incompatible with strong oxidizing agents (NIOSH, 2016).
Reactivities and Incompatibilities
Ignition occurs when potassium tert-butoxide reacts with … n-propanol …
Contact with strong oxidizers may cause fires and explosions.
Strong oxidizers.
The vapor mixes well with air; explosive mixtures are easily formed. Reacts with strong oxidants (perchlorates, nitrates).
Contact of 1.5 g portions of the solid butoxide /potassium tert-butoxide/ with drops of the liquid (l) or with the vapors (v) of the reagents below caused ignition … .
Strong oxidizers

 

 

 

 

 

 

CAS NO:71-23-8

SYNONYMS
1-propanol;propanol;Propan-1-ol;n-propanol;Propyl alcohol;71-23-8;n-Propyl alcohol;ethylcarbinol;1-hydroxypropane;optal;osmosol extra;Propylic alcohol;Propanol-1;1-Propyl alcohol;n-Propan-1-ol;Propanolen;Propanole;Alcohol, propyl;Propanoli;Ethyl carbinol;Alcool propilico;Alcool propylique;n-Propyl alkohol;Propylowy alkohol;Albacol;1 Propanol;propane-1-ol;Propanole [German];Propanolen [Dutch];Propanol, 1-;Propanoli [Italian];propylalcohol;Propyl alcohol, normal;Caswell No. 709A;1-PROPONOL;FEMA Number 2928;Propyl alcohol (natural);n-Propyl alkohol [German];Alcool propilico [Italian];Alcool propylique [French];Propylowy alkohol [Polish];NSC 30300;UNII-96F264O9SV;FEMA No. 2928;CCRIS 3202;HSDB 115;Propylan-propyl alcohol;EINECS 200-746-9;UN1274;RL04721;RTR-023458;TRA0060291;1-Propanol, ACS reagent, >=99.5%;1-Propanol, HPLC grade, >=99.5%;CAS-71-23-8;1-Propanol, purum, >=99.0% (GC);NCGC00255163-01;AN-41945;KB-66585;1-Propanol, SAJ first grade, >=99.0%;Propyl Alcohol (Normal) Reagent Grade ACS;TR-023458;FT-0608280;FT-0627482;P0491;1-Propanol, UV HPLC spectroscopic, 99.0%;2537-EP2269989A1;2537-EP2269993A1;2537-EP2269994A1;2537-EP2295053A1;2537-EP2298313A1;27313-EP2311808A1;27313-EP2311829A1;27313-EP2311830A1;27313-EP2314575A1;136983-EP2275411A2;136983-EP2292606A1;A837125;I14-2607;InChI=1/C3H8O/c1-2-3-4/h4H,2-3H2,1H;J-505102;1-Propanol, for inorganic trace analysis, >=99.8%;1-Propanol, B&J Brand (product of Burdick & Jackson);F0001-1829;Z955123580;1-Propanol, puriss. p.a., Reag. Ph. Eur., >=99.5% (GC);1-Propanol, United States Pharmacopeia (USP) Reference Standard;n-Propanol or propyl alcohol, normal [UN1274] [Flammable liquid];n-Propanol or propyl alcohol, normal [UN1274] [Flammable liquid];1-Propanol, Pharmaceutical Secondary Standard; Certified Reference Material;5VQ

N-Propanol, CH3CH2CH2OH formülüyle (bazen PrOH veya n-PrOH olarak temsil edilen) bir birincil alkoldür. Bu renksiz sv ayrca propan-1-ol, 1-propil alkol, n-propil alkol ve n-propanol olarak bilinir. 2-propanolün (propan-2-ol, izopropil alkol, izopropanol) bir izomeridir. Pek çok fermantasyon ilemi srasnda doal olarak az miktarlarda oluur ve esas olarak reçineler ve selüloz esterleri için farmasötik endüstrisinde bir çözücü olarak kullanlr.

KMYASAL ÖZELLKLER
1-Propanol, bir birincil alkolün normal reaksiyonlarn gösterir. Böylece alkil halitlere dönütürülebilir; örnein, krmz fosfor ve iyodin,% 80 verimle n-propil iyodür üretirken, katalitik ZnCl2 içeren PC1, n-propil klorür verir. Fischer esterifikasyon koullar altnda bir H2S04 katalizörünün varlnda asetik asit ile reaksiyon, propil asetat verirken, tek bana formik asit ile propanolün gece boyunca geri aktlmas,% 65 verimle propil format üretebilir. 1-propanolün Na2Cr207 ve H2S04 ile oksidasyonu sadece% 36’lk bir propionaldehid verimi verir ve bu nedenle bu tip reaksiyon için PCC veya Swern oksidasyonu kullanan daha yüksek verimli yöntemler tavsiye edilir. Kromik asit ile oksidasyon, propionik asit verir.

HAZIRLIK
1-Propanol, propionaldehid’in katalitik hidrojenasyonu ile üretilir. Propionaldehid, okso prosesi yoluyla, karbon monoksit ve hidrojen kullanlarak, etilenin, kobalt oktakarbonil veya bir rodyum kompleksi gibi bir katalizörün varlnda hidroformilasyonu ile üretilir.
H2C = CH2 + CO + H2 → CH3CH2CH = O
CH3CH2CH = O + H2 → CH3CH2CH2OH
1-propanolün geleneksel bir laboratuar preparasyonu n-propil iyodürün nemli Ag20 ile muamele edilmesini içerir.
N-Propanol, 1853’te, fnd petrolün fraksiyonel damtlmasyla elde edilen Gustave C. B. Chancel tarafndan kefedilmitir. Gerçekten de, 1-propanol, patates veya tahllar etanol üretmek üzere fermente edildiinde, belirli amino asitlerden oluturulmu bir yan ürün olan fusel yann ana bileenidir. Bu süreç artk önemli bir 1-propanol kayna deildir.
EMNYET
N-Propanol’ün insan vücudu üzerindeki etkilerinde etanol ile benzer olduu düünülür, ancak 2-4 kat daha güçlüdür. Sçanlarda Oral LD50, 1870 mg / kg’dr (etanol için 7060 mg / kg’a kyasla). Propionik aside metabolize edilir. Etkileri
Alkolik intoksikasyon ve yüksek anyon boluu metabolik asidozu içerir. 2011 yl itibaryla sadece bir vakada öldürücü 1-propanol zehirlenmesi bildirilmitir.

SOLUNUM
Bu yöntem nadir olmakla birlikte, var. Propanol, nebulizatörlerle olan etkilerinden dolay inhalasyon için etanolden çok daha uygun olabilir.
Propanol yakt olarak
1-propanol yüksek oktan saysna sahiptir ve motor yakt kullanm için uygundur. Bununla birlikte, propanol üretimi, onu ortak bir yakt haline getirmek için çok pahal olmutur. Propanolün aratrma oktan says (RON) 118, anti-vuruntu indeksi (AKI) 108’tir.

GÜVENLK VE TEHLKELER
Tehlike TANITIMI
GHS Tehlike fadeleri
2587 irket tarafndan 43 bildiriden ECHA C & L Envanterine salanan toplam GHS bilgileri. Her bildirim birden çok irketle ilikilendirilebilir.
2587 firmann 1’inde GHS tehlike kriterlerini karlamad bildirildi. Daha detayl bilgi için lütfenECHA C & L web sitesini ziyaret ediniz.
2587 sayl 2587 firmann tehlike bildirimi koduna sahip 42 bildirim (ler) inden:

H225 (% 100): Yüksek derecede yanc sv ve buhar [Tehlikeli Yanc svlar]
H302 (% 13.96): Yutulduunda sala zararldr [Uyar Akut toksisite, oral]
H318 (% 100): Ciddi göz hasarna neden olur [Tehlike Ciddi göz hasar / göz tahrii]
H336 (% 99.81): Uyuuklua veya ba dönmesine neden olabilir [Uyar Spesifik hedef organ toksisitesi, tek maruz kalma; Narkotik etkiler]

Bilgiler, kirliliklere, katk maddelerine ve dier faktörlere bal olarak bildirimler arasnda deiebilir. Parantez içindeki yüzde deeri, tehlike kodlar salayan firmalardan bildirilen snflandrma orann gösterir. Sadece% 10’un üzerindeki yüzde deerlerine sahip tehlike kodlar gösterilir.

Önlem fadesi Kodlar
P210, P233, P240, P241, P242, P243, P261, P264, P270, P271, P280, P301 + P312, P303 + P361 + P353, P304 + P340, P305 + P351 + P338, P310, P312, P330, P370 + P378, P403 + P233, P403 + P235, P405 ve
Salk tehlikesi
Gözle temas ar derecede tahri edicidir ve yanklara neden olabilir. Buharlar burun ve boaz tahri eder. Yüksek konsantrasyonlarda, bulant, ba dönmesi, ba ars ve stupor neden olabilir. (USCG, 1999)
Yanc – 3 derece
Yangn tehlikesi
ERG Guide’dan alnt 129 [Yanc Svlar (Suyla karabilir / Zararl)]: YÜKSEK YANICI: Is, kvlcm veya alevle kolayca tutuur. Buharlar hava ile patlayc karmlar oluturabilir. Buharlar ateleme kaynana gidebilir ve geri dönebilir. Çou buhar havadan daha ardr. Yaylacaklar zeminde ve düük veya snrl alanlarda (kanalizasyon, bodrum, depo) toplayn. Buhar patlama tehlikesi içeride, darda veya kanalizasyonda. Bir (P) ile belirtilen maddeler stldnda veya bir yangna kartnda patlayc olarak polimerize olabilirler. Kanalizasyona aktlmas yangn veya patlama tehlikesi yaratabilir. Kaplar stldnda patlayabilir. Birçok sv sudan daha hafiftir.
Son derece yanc. Yangnda tahri edici veya zehirli dumanlar (veya gazlar) verir. Buhar / hava karmlar patlaycdr.

Yangn potansiyeli
Isya veya aleve maruz kaldnda tehlikeli; Oksitleyici maddeler ile kuvvetlice reaksiyona girebilir.
Potasyum-tert-butoksit ile temasta tutuur.
Deri, Göz ve Solunum Tahrii
3 T0 5 MIN ÇN 400 PPM’YE MARUZ KALMA ETKLER, BURUN VE BTKLERNN ÜRETLMES.
Yüksek konsantrasyon … CNS depresyonuna neden olabilir ve gözler, boaz ve mukoza zarlarn tahri eder. Svlarn cilde temas etmesi, hafif kimyasal yanklara neden olabilir.

Güvenlik ve Tehlikeli Özellikler
LEL
% 2.1 (USCG, 1999)
% 2.2
UEL
% 13,5 (USCG, 1999)
% 13.7

Yanclk
Alt yanc limit: hacimce% 2.2; Üst yanc limit: Hacmen% 13,7
Snf IB Yanc Sv: Fl.P. 73 ° F’nin altnda ve BP 100 ° F veya üstünde.
Kritik scaklk
Kritik scaklk: 263.7 deg C; kritik basnç: 51 atm
Kritik Basnç
Kritik scaklk: 263.7 deg C; kritik basnç: 51 atm
NFPA Tehlike Snflandrmas
Salk: 1. 1 = Maruz kaldnda tahrie neden olabilecek malzemeler, ancak onaylanm hava temizleyici bir solunum cihaznn kullanlmasn gerektirenler de dahil olmak üzere sadece küçük kalnt yaralanmalar. Bu malzemeler salk için sadece biraz tehlikelidir ve sadece solunum korumas gereklidir.
Yanabilirlik: 3. 3 = Bu derece, hemen hemen tüm normal scaklk koullarnda kolayca tutuabilen Snf IB ve IC yanc svlar ve malzemeleri içerir. Bu tür malzemelerdeki yangnlar kontrol etmek veya söndürmek için su etkisiz olabilir.
Reaktivite: 0 0 = Bu derece, yangna maruz kalma koullarnda bile normalde stabil olan ve suyla reaksiyona girmeyen malzemeleri içerir. Normal yangnla mücadele prosedürleri kullanlabilir.

NFPA Yangn Snf
3
NFPA Salk Deerlendirmesi
1
Fiziksel Tehlikeler
Buhar hava ile iyi karr, patlayc karmlar kolayca oluur.
Kimyasal Tehlikeler
800 ppm
Güçlü oksitleyicilerle reaksiyona girer. Bu yangn ve patlama tehlikesi oluturur. Baz plastik ve kauçuk formlarna saldrr.
Patlayc Limitler ve Potansiyel
% 2.1, ÜST% 13,5
Is veya aleve maruz kaldnda buhar eklinde patlaycdr.
Patlayc limitler, havadaki vol%: 2.1-13.5
OSHA Standartlar
zin Verilen Maruz Kalma Limiti: Tablo Z-1 8-hr Zaman Arlkl Ort: 200 ppm (500 mg / cu m).
Açklanm OSHA PEL TWA 200 ppm (500 mg / cu m); Baz eyaletlerde 250 ppm STEL (625 mg / cu m) hala uygulanmaktadr.
NIOSH Önerileri
Önerilen Maruz Kalma Limiti: 10 Saat Zaman Arlkl Ort: 200 ppm (500 mg / cu m).
Önerilen Maruz Kalma Limiti: 15 Dak Ksa Süreli Maruz Kalma Snr: 250 ppm (625 mg / cu m) [cilt].
lk YARDIM TEDBRLER
lk yardm
Göz: Bu kimyasal göze temas ederse, gözlerinizi derhal bol miktarda suyla ykayn, bazen alt ve üst kapaklar kaldrn. Hemen tbbi yardm aln. Bu kimyasal ile çalrken kontakt lensler giyilmemelidir. Cilt: Bu kimyasal cilde temas ederse, kontamine deriyi suyla ykayn. Deri tahriine dair kantlar olduunda, tbbi yardm aln. Solunum: Bir kii bu kimyasaln büyük miktarn soluduunda, maruz kalan kiiyi bir defada temiz havaya çkarn. Solunum durduysa, azdan aza yeniden canlandrn. Etkilenen kiiyi scak ve dinlendirin. En ksa sürede tbbi yardm aln. Yutulmas: Bu kimyasal yutulduysa hemen tbbi yardm aln.

Göz: Hemen sulayn
Cilt: Su sifonu
Solunum: Solunum destei
Yutmak: hemen tbbi yardm
Soluma lk Yardm
Temiz hava, dinlen.

Cilt lk Yardm
su ve sabun ile ykayn, sonra durulayn ve.
Göz lkyardm
lk önce birkaç dakika bol su ile durulayn (eer mümkünse kontak lensleri çkarn), ardndan tbbi yardm aln.
Yutma lk Yardm
Az çalkalayn. Tbbi yardm aln.
Yangnla Mücadele Tedbirleri
Yangnla mücadele etmek için alkol köpüü, karbon dioksit, kuru kimyasal kullann.
/ Yangn söndürme srasnda ya da dier pozitif basnç modunda çaltrlan tam yüz maskesine sahip, kendi kendine yeten solunum cihaz / yangn söndürme cihaz kullanlmaldr.

Yangn söndürme
ERG Guide’dan alnt 129 [Yanc Svlar (Suyla karabilir / Zararl)]: DKKAT: Tüm bu ürünler çok düük bir parlama noktasna sahiptir: Yangn söndürürken su spreyi kullanlmas verimsiz olabilir. KÜÇÜK YANGIN: Kuru kimyasal, CO2, su püskürtme veya alkole dirençli köpük. Nitrometan (UN 1261) veya nitroetan (UN2842) içeren yangnlar kontrol etmek için kuru kimyasal yangn söndürücüler kullanmayn. BÜYÜK YANGIN: Su spreyi, sis veya alkole dirençli köpük. Düz aklar kullanmayn. Risk almadan yapabiliyorsanz kaplar yangn alanndan uzaklatrn. YANGIN ÇEREN TANKLAR VEYA ARABA / RÖMORK YÜKLER: Maksimum mesafeden atele savan veya insansz hortum tutucular kullann veya nozullar izleyin. Yangn bittikten sonra su miktarn az olan serin kaplar söndürülür. Havalandrma güvenlik cihazlarndan gelen yükselen ses veya tankn renginin solmas durumunda derhal geri çekilmelidir. HER ZAMAN yangnda yutulmu tanklardan uzak durun. Büyük yangnlar için insansz hortum tutucular kullann veya nozullar izleyin; Bu mümkün deilse, alandan çekilip ate yakmasna izin verin.
Su spreyi, toz, alkole dirençli köpük, karbon dioksit kullann. Yangn durumunda: davul vb.
Dier Yangnla Mücadele Tehlikeleri
Buhar izi boyunca geriye doru yanp sönebilir.
zolasyon ve Tahliye
ERG Guide’dan alnt 129 [Yanc Svlar (Suyla karabilir / Zararl)]: Hemen önlem olarak, dökülme veya sznt bölgesini her yönden en az 50 metre (150 feet) izole edin. BÜYÜK DÖKÜM: lk aa rüzgar tahliyesini en az 300 metre (1000 fit) düünün. YANGIN: Eer tank, demir yolu veya tank kamyonu yangna karyorsa, ISOLATE her yöne 800 metre (1/2 mil); Ayrca, tüm yönlerde 800 metre (1/2 mil) için ilk tahliye düünün. (ERG, 2016)
Dökülme Bertaraf
Havalandrma. Tüm ateleme kaynaklarn çkarn. Szdran ve dökülen svy szdrmaz kaplarda mümkün olduunca toplayn. Kalan svy kum veya inert absorbanda emdirin. Daha sonra yerel düzenlemelere göre saklayn ve atn.

TEMZLEME YÖNTEMLER
Kat üzerine emdirin. Balktaki bir bardak veya demir tabak üzerine buharlatrn. Kad yak.
Dökülmeleri tedavi etmek için önerilen kar önlemler: aktif kömür, biyolojik artma maddesi, jelletirici ajan, emici madde, datc madde.
Bertaraf Yöntemleri
SRP: nceleme srasnda, arazi artma veya gömme (shhi depolama sahas) bertaraf uygulamalar için kriterler önemli bir revizyona tabidir. Atk kalntlarnn (atk çamuru dahil) arazi imha edilmesinden önce, kabul edilebilir bertaraf uygulamalar hakknda rehberlik için çevre düzenleme kurulularna dann.
1. Vermikulit, kuru kum, toprak veya benzeri bir malzemeyi emerek ve … / onaylanm / düzenli bir depolama sahasnda bertaraf ederek. 2. Uygun bir yanma odasnda atomize ederek.
Aadaki atk su artma teknolojileri n-propanol için aratrlmtr: Biyolojik artma.
Yakma: Atk sv bir yakma frn içinde atomize olabilir veya lisansl bir çözücü bertaraf irketi araclyla imha edilebilir veya geri kazanlabilir.

SRP: Bulaan koruyucu kyafetler, giysiyi tutan, imha eden veya temizleyen personel tarafndan dorudan kiisel temasta bulunmayacak ekilde ayrlmaldr. Temizlik prosedürlerinin tam olup olmadn tespit etmek için kalite güvencesi, dekontamine koruyucu giysilerin içiler tarafndan yeniden kullanlmas için iade edilmeden önce uygulanmaldr. Kirlenmi kyafetler vardiya sonunda eve götürülmemelidir, ancak çalanlarn temizlik için i yerinde kalmaldr.
Sv izobütil alkolle çalan çalanlar, yemeden veya sigara içmeden önce ellerini ykamaldr. / zobütil alkol /
çi kirlendiinde derhal derhal ykamaldr.
Islanan kyafetler, yanclk tehlikesi nedeniyle hemen çkarlmaldr.
TAIMA VE DEPOLAMA
Yanmaz Dökülme Tepkisi
ERG Guide’dan alntlar 129 [Yanc Svlar (Suyla karabilir / Zararl)]: Tüm ateleme kaynaklarn (derhal sigara içilmez, iaret fiei, kvlcm veya alev almaz) ELEMNE EDN. Ürünü kullanrken kullanlan tüm ekipman topraklanmaldr. Dökülen malzemeye dokunmayn ya da yürüymeyin. Risk olmadan yapabiliyorsanz sznty durdurun. Su yollarna, kanalizasyona, bodrum katlarna veya kapal alanlara girii engelleyin. Buharlar azaltmak için buhar bastrma köpüü kullanlabilir. Kuru toprak, kum veya dier yanc olmayan materyallerle emdirin veya kaplayn ve kaplara aktarn. Emilen malzemeyi toplamak için temiz, kvlcm çkarmayan aletler kullann. BÜYÜK DÖKÜLMES: Daha sonra bertaraf edilmek üzere sv dökülmesinin çok ötesine geçin. Su spreyi buhar azaltabilir, ancak kapal alanlarda tutumay engelleyemeyebilir. (ERG, 2016)
Güvenli depolama
Yanmaz. Güçlü oksitleyicilerden ayrlr. Güzel. yi kapal. yi havalandrlm bir odada saklaynz.
Depolama koullar
Kaplar kapal tutun, serin, iyi havalandrlm bir yerde tutuma kaynaklarndan uzakta saklayn.
Maruz Kalma Kontrolü ve Kiisel Korunma
REL
TWA 200 ppm (500 mg / m3) ST 250 ppm (625 mg / m3) [cilt]
PEL-TWA
200 ppm (500 mg / m³) ppm
REL-TWA
200 ppm (500 mg / m³) ppm
REL-STEL
250 ppm (625 mg / m³) ppm
IDLH
800 ppm (NIOSH, 2016)
800 ppm ppm
800 ppm

Eik Snr Deerleri
8 saat Zaman Arlkl Ort (TWA): 100 ppm

Gezi Snr Tavsiyesi: çi maruziyet düzeylerindeki gezintiler, bir i günü boyunca toplamda 30 dakikadan fazla olmamak kouluyla TLV-TWA’nn 3 katn geçemez ve TLV-TLS’nin 5 katn geçmemelidir. TWA almam.
A4: nsan kanserojen olarak snflandrlamaz.
TWA olarak 100 ppm; A4 (insan kanserojen olarak snflandrlamaz)

Dier Mesleki zin Verilen Seviyeler
Dier öneriler: Bat Almanya (1974) 200 ppm; Çekoslovakya (1969), Dou Almanya (1973) 100 ppm; SSCB (1972) 50 ppm.
Bu maddenin 20 ° C’de buharlamasyla havann zararl bir ekilde kirlenmesine; Bununla birlikte, püskürtme veya datma konusunda çok daha hzldr.
Ksa Vadeli Maruz Kalmann Etkileri
Bu madde gözü tahri eder. Bu madde merkezi sinir sistemi üzerinde etkilere neden olabilir. Yüksek seviyelerde maruz kalmak bilinç kaybna neden olabilir.
Uzun Süreli Maruziyetin Etkileri
Bu madde kurumaya ve çatlamaya neden olabilecek deriye kar koymaktadr.

zin verilen Toleranslar
N-propanol kalntlar, iyi tarmsal uygulamalara uygun olarak, tarmsal uygulamalara uygun olarak, yetitiricilere veya hasattan sonra ham tarmsal ürünlere uygulanan pestisit formülasyonlarnda, inert (veya ara sra aktif) bileenler olarak kullanldnda, bir tolerans gerekliliinden muaf tutulur.
n-Propanol, kark tarm ilaçlar için, iyi tarm uygulamalarna uygun bir çözücü olarak kullanldnda tolerans gerekliliinden muaftr, ancak, sadece büyüyen ürünlere uygulanan pestisit formülasyonlarnda, inert (veya ara sra aktif) bileenler olarak kullanlr.
n-Propanol, hayvanlara uygulanan pestisit formülasyonlarnda inert (veya ara sra aktif) terkip maddeleri olarak iyi bir tarm uygulamasna uygun olarak harmanlanm emülsiyonlatrclar için bir çözücü olarak kullanldnda bir tolerans gerekliliinden muaftr.
Kiisel koruma

Cilt: Ciltle temas önleyin
Gözler: göz temas önlemek
Deriyi ykayn: Kirlendiinde
Çkarn: Islak olduunda (yanc)
Deitir: Öneri yok

Solunum Önerileri
NIOSH / OSHA
800 ppm’e kadar:
(APF = 10) Organik buhar kartulu kimyasal koruyucu kartu *
(APF = 25) Organik buhar kartuu (kartular) ile güçlendirilmi, hava arndrc bir respiratör *
(APF = 50) Çene tarz, ön veya arkaya monteli organik buhar kab ile hava temizleyici, tam yüz maskesi (gaz maskesi)
(APF = 10) Verilen herhangi bir hava respiratörü *
(APF = 50) Tam yüz yüze her türlü solunum aparat
Bilinmeyen konsantrasyonlara veya IDLH koullarna acil veya planl giri:
(APF = 10.000) Tam yüz yüze sahip ve her türlü solunum cihazbir basnç talebi veya baka bir pozitif basnç modunda çaltrlr
(APF = 10.000) Tam yüz yüze olan ve kendi kendine yeten bir pozitif basnçl solunum cihaz ile birlikte basnç talebi veya baka bir pozitif basnç modunda çalan herhangi bir solunum havas respiratörü
Kaç:
(APF = 50) Çene tarz, ön veya arkaya monteli organik buhar kab ile hava temizleyici, tam yüz maskesi (gaz maskesi)
Uygun bir kaç tipi, bamsz solunum aparat
Yangn Önleme
NO açk alev, kvlcm ve sigara içilmez. Oksitleyici maddeler ile temas ettirilmez. Kapal sistem, havalandrma, patlamaya dayankl elektrik ekipman ve aydnlatma. Doldurma, boaltma veya kullanma için basnçl hava KULLANMAYIN.
Soluma Önleme
Havalandrma, yerel egzoz veya solunum korumas kullann.
Cilt Önleme
Koruyucu eldivenler.
Göz önleme
Koruyucu gözlük takn.
Yutma Önleme
Çalrken yemek yemeyin, içmeyin veya sigara kullanmayn.
Koruyucu Ekipman ve Giyim
Cilt: Cildin temasn önlemek için uygun kiisel koruyucu kyafet giyin. Gözler: Gözle temas önlemek için uygun göz korumas takn. Cildi ykayn: çi kirlendiinde derhal derhal ykamaldr. Çkarma: Islanan i kyafeti yanclk tehlikesi nedeniyle hemen çkarlmaldr (örn. Parlama noktas <100 ° F olan svlar için). Deiim: çinin i vardiyasndan sonra giysiyi deitirmesi gerektiini belirten bir öneri yoktur. (NIOSH, 2016)
Çalanlar, sv propil alkol ile tekrarlanan veya uzun süreli ciltle temas önlemek için gerekli olan, geçirimsiz kyafetler … ve dier uygun kyafetler ile birlikte verilmeli ve gereklidir. … Çalanlara, sv propil alkolün gözlerle temas edebilecei yerlerde su geçirmez güvenlik gözlükleri kullanlmal ve kullanlmaldr.
Lastik eldiven giyin, yüz siperi, tulum ….
Neopren ve nitril kauçuk için iki veya daha fazla test cihaz tarafndan rapor edilen bir saatten büyük süreler. Bir saatten daha büyük atlm süreleri öneren baz veriler (genellikle daldrma testlerinden) doal kauçuk için uygun deildir. Bütil kauçuk, neopren / stiren-bütadien kauçuk, polivinil klorür, polietilen, poliüretan, polivinil alkol ve viton için veri yoktur. Polivinil klorür (PVC) için yaklak bir saat ya da daha fazla atlm sürelerini gösteren baz veriler.
Cildin temasn önlemek için uygun kiisel koruyucu kyafetler giyin.
Göz temasn önlemek için uygun göz korumas takn.

Solunum cihaz seçimi için öneriler. Maksimum kullanm için uygun: 800 ppm. Solunum Snf (lar) : Organik buhar kartuu (kartular) olan herhangi bir kimyasal kartu respiratörü. Göz korumas gerektirebilir. Organik buhar kartuu (kartular) ile güçlendirilmi, hava arndrc bir respiratör. Göz korumas gerektirebilir. Çene tarz, ön veya arkaya monteli organik buhar kab ile hava temizleyici, tam yüz maskesi (gaz maskesi). Salanan herhangi bir solunum maskesi. Göz korumas gerektirebilir. Tam yüz yüze sahip bamsz solunum cihaz.
Solunum cihaz seçimi için öneriler. Durum: Bilinmeyen birleik veya IDLH koullarna acil veya planl giri: Solunum Snf (lar): Tam yüz yüze olan ve basnç talebi veya baka bir pozitif basnç modunda çalan bamsz solunum cihaz. Basnçl veya dier pozitif basnçl modda çaltrlan bir yardmc solunum aparat ile birlikte tam bir yüzeye sahip olan ve basnç talebi veya baka bir pozitif basnç modunda çaltrlan herhangi bir solunum havas respiratörü.
Solunum cihaz seçimi için öneriler. Durum: Aniden ortaya çkan solunum tehlikelerinden kaçmak: Solunum Snf (lar): Çene tarz, ön veya arkaya monte edilmi organik buhar kab ile hava temizleyici, tam yüz maskesi (gaz maskesi). Uygun bir kaç tipi, bamsz solunum aparat.

KARARLILIK VE REAKTVTE
Hava ve Su Reaksiyonlar
Son derece yanc. Suda çözünür.
Alkoller ve Polioller
Reaktivite Uyarlar
Son derece yanc
Reaktivite Profili
N-PROPANOL, yanc ve / veya toksik gazlar vermek için alkali metal, nitritler ve güçlü indirgeyici maddeler ile reaksiyona girer. Esterleri ve suyu oluturmak için oksoasitler ve karboksilik asitlerle reaksiyona girer. Oksitleyici maddeler tarafndan propanal veya propionik aside dönütürülür. zosiyanat ve epoksitlerin polimerizasyonunu balatabilir. Güçlü oksitleyici maddelerle uyumsuzdur (NIOSH, 2016).
Tepkiler ve Uyumsuzluklar
Potasyum tert-bütoksit … n-propanol ile reaksiyona girdiinde ateleme oluur.
Güçlü oksitleyicilerle temas, yangn ve patlamalara neden olabilir.
Güçlü oksitleyiciler.
Buhar hava ile iyi karr; Patlayc karmlar kolaylkla oluturulabilir. Güçlü oksitleyicilerle (perkloratlar, nitratlar) reaksiyona girer.
Kat butoksit / potasyum tert-butoksitin 1.5 g’lk ksmlarnn / svlarn (l) damlalar ile veya aadaki reaktiflerin buharlar (v) ile temas, atelemeye neden oldu.
Güçlü oksitleyiciler

 

Explore: